PCB Material Specification Sheet
ROGERS

SDS – RO3000 Series Laminates – Fr

Compliant with Regulation (EC) No 1907/2006 (REACH) and CLP Regulation (EC) No 1272/2008

1. Identification of the Product and Company

  • Product Name: RO3000® Series Laminates
  • Recommended Applications: High-frequency circuit materials for RF and microwave applications.
  • Manufacturer: Rogers Corporation

For emergencies, contact local authorities or poison control centers.

2. Hazard Identification

  • CLP Classification:
    The RO3000® series laminates are not classified as hazardous under CLP regulations.
  • Main Risks:
    • Dust formation during drilling or mechanical cutting.
    • Potential thermal decomposition (toxic fumes).
  • Hazard Pictograms: None required.

3. Composition/Information on Components

Substance/ComponentPercentageCAS NumberClassification
PTFE (Polytetrafluoroethylene)40–70%9002-84-0Not classified
Ceramic Filler30–60%Not applicableNot classified
Copper (Copper Cladding)Variable7440-50-8Not classified

4. First Aid Measures

  • Inhalation: Move the person to fresh air. If symptoms persist, seek medical attention.
  • Skin Contact: Wash with soap and water.
  • Eye Contact: Rinse thoroughly with water for at least 15 minutes.
  • Ingestion: Not applicable (solid material).

5. Firefighting Measures

  • Suitable Extinguishing Media: Water, foam, carbon dioxide (CO₂), dry powder.
  • Specific Hazards: Potential release of toxic fumes during combustion (e.g., hydrogen fluoride, carbon monoxide).
  • Protective Equipment: Wear self-contained breathing apparatus and protective clothing.

6. Accidental Release Measures

  • Personal Precautions: Wear gloves and a dust mask when handling residues or debris.
  • Environmental Precautions: Prevent debris from entering drains or waterways.
  • Cleanup Methods: Collect mechanically and dispose of in accordance with local regulations.

7. Handling and Storage

  • Handling:
    • Wear gloves and safety glasses during machining.
    • Minimize dust generation.
  • Storage:
    • Store in a dry, well-ventilated area.
    • Recommended temperature: 20–25°C (68–77°F).

8. Exposure Controls/Personal Protection

  • Exposure Limits: No specific limits for the components.
  • Personal Protective Equipment:
    • Respiratory Protection: Dust mask (FFP2/FFP3) during machining.
    • Eye Protection: Safety glasses.
    • Hand Protection: Cut-resistant gloves.

9. Physical and Chemical Properties

PropertyValue
FormRigid sheet
ColorWhite or copper-colored
OdorOdorless
Decomposition Temperature> 500°C
SolubilityInsoluble in water

10. Stability and Reactivity

  • Chemical Stability: Stable under normal use and storage conditions.
  • Hazardous Decomposition Products: Fumes of hydrogen fluoride, carbon monoxide, carbon dioxide.

11. Toxicological Information

  • Acute Toxicity: Not applicable (solid inert material).
  • Long-term Effects: No known hazard under normal exposure conditions.

12. Ecological Information

  • Ecotoxicity: Inert material, non-toxic to the environment.
  • Persistence and Degradability: Non-biodegradable.
  • General Considerations: Avoid dispersal into the environment.

13. Disposal Considerations

  • Disposal Methods:
    • Recycle where possible.
    • Dispose of in compliance with local regulations.

14. Transport Information

  • Regulations: Not classified as hazardous for transport (ADR/RID/IMDG/IATA).

15. Regulatory Information

  • EU Labeling: No special labeling required.
  • Local Regulations: Compliant with European REACH and CLP regulations.

16. Other Information

  • This safety data sheet has been prepared in accordance with current regulations.
  • The information contained herein is accurate to the best of our knowledge as of the date of publication.

Author

Eleanor

Leave a comment

Your email address will not be published. Required fields are marked *