PCB Material Specification Sheet
ROGERS

RO3000 Series Bondply Data Sheet Processing Guidelines

The RO3000® Series Bondply is a high-frequency adhesive material used in the lamination of RO3000® series laminates. This material provides excellent bonding strength, electrical performance, and compatibility with a variety of RF and microwave applications.

1. Product Overview

RO3000® Bondply is a ceramic-filled PTFE adhesive layer designed to laminate high-frequency circuit materials, particularly the RO3000® series laminates. It offers stable dielectric properties, low loss, and robust adhesion to meet the demands of multilayer RF designs.

2. Key Features

  • Low Dielectric Loss: Maintains signal integrity in RF applications.
  • Stable Dielectric Constant (Dk): Provides consistent performance across temperature and frequency ranges.
  • Thermal Stability: Supports reliable performance in thermal cycling environments.
  • Excellent Adhesion: Strong bond with both copper and PTFE-based laminates.
  • Ease of Use: Compatible with standard PCB manufacturing and lamination processes.

3. Material Properties

PropertyTypical Value
Dielectric Constant (Dk)~2.94 ± 0.05 (at 10 GHz)
Dissipation Factor (Df)0.0015 (at 10 GHz)
Peel Strength≥ 7 lbs/in (1.2 N/mm)
Thermal Conductivity0.25 W/m·K
Coefficient of Thermal Expansion (CTE), X, Y~50 ppm/°C
Coefficient of Thermal Expansion (CTE), Z~100 ppm/°C
Water Absorption< 0.1%
Decomposition Temperature (Td)> 500°C

4. Available Configurations

  • Thickness: Available in 0.002” (50 µm) to 0.010” (250 µm).
  • Roll or sheet formats.
  • Compatible with various copper cladding options.

5. Processing Guidelines

A. Storage and Handling
  • Store in a cool, dry environment (20–25°C, 30–50% RH).
  • Avoid exposure to direct sunlight and contaminants.
  • Use clean gloves when handling to prevent surface contamination.
B. Lamination Guidelines
  • Preparation: Ensure surfaces are clean and free from debris. Plasma or chemical cleaning is recommended.
  • Lamination Cycle:
    • Temperature: 200–230°C (392–446°F).
    • Pressure: 300–500 psi.
    • Time: Maintain temperature and pressure for 30–60 minutes, depending on laminate thickness.
  • Cooling: Cool under pressure to avoid warping or delamination.
C. Drilling
  • Use carbide or diamond-coated bits to achieve clean hole walls.
  • Minimize stack height to reduce resin smear.
  • Perform post-drill cleaning to ensure through-hole quality.
D. Etching and Plating
  • Compatible with standard etching and plating techniques.
  • Use electroless copper plating for uniform conductivity.
E. Soldering and Assembly
  • Use standard reflow or vapor phase soldering methods.
  • Avoid excessive mechanical stress to preserve structural integrity.

6. Applications

7. Compliance and Certifications

  • RoHS Compliant: Yes
  • REACH Compliant: Yes
  • UL Listed: UL 94 V-0 for certain configurations

8. Safety and Handling

  • Wear appropriate PPE to avoid exposure to dust or fumes during processing.
  • Ensure adequate ventilation in lamination and machining areas.
  • Dispose of scrap material according to local regulations.